Dye Penetrant Test
Aside from
the hermeticity testing methods discussed above, the Dye
Penetrant Test
is another age-old FA technique useful in analyzing hermeticity
failures. It is performed to identify leakage paths
within packages that exhibit hermetic
failures.
The Dye
Penetrant Test consists of the following steps:
1) immersion
of the sample in a
fluorescent dye such as Zyglo; 2)
pressurization of the dye solution in
a pressure chamber to about 90 psig for about 8 hours; 3)
rinsing of the sample in acetone
followed by air drying; 4) examination of the sample
under an ultraviolet
lamp, which will make traces of Zyglo visible.
The analyst must
thoroughly inspect the package to
identify spots where Zyglo is leaking out of the sample. After all
the leakage points have been identified,
the analyst may delid the sample to further check
where the Zyglo entered the package in order to isolate the point of
hermeticity failure.
Examples of What Hermeticity Testing Can Detect:
1)
cerdip seal glass cracks or holes;
2)
multilayer package seal cracks or holes;
3) inadequate metal can welding;
4)
header glass eyelet cracks;
5) microcracks in hermetic packages;
6)
incomplete sealing in hermetic packages;
7)
non-wetting issues in combo lid solder seals