<Back to Page 1>
Air
ionization is just one component of a complete static control program.
It must not be a substitute for grounding or other methods.
Ionizers are used when it is not possible to properly ground everything,
or simply as a backup to other static control methods. In clean rooms, air
ionization may be one of the few methods of static control available.
LINKS:
The ionization
characteristics of air ionizers must be checked regularly, since an
improperly working air ionizer can emit a unbalanced stream of
positive and negative ions. If that happens, the air ionizer itself
would accelerate a static charge build-up, and be the root cause of a
serious ESD problem on the line.
Fig. 7.
Examples of bench-top ionizers
Fig. 8.
Examples of overhead ionizers
Protection of Products
from ESD
ESD-sensitive
devices must never leave a plant unless they are properly protected from
ESD. Direct protection of devices from ESD can be provided by properly
selected packaging materials such as antistatic bags. Even intra- or
inter-factory transport of devices must be done with the use of ESD-protective
carriers.
ESD-protective packaging
materials must: 1) be dissipative; 2) exhibit low triboelectric charging
tendency; and 3) have the ability to shield their contents from
electrostatic fields.
The insides of these packaging materials have a low charging layer, while
their outer layers have a surface resistivity that's within the dissipative
range.
Dissipative
materials have a surface resistance greater than 104
but less than or equal to 1011 ohms when tested according to
EOS/ESD-S11.11 or a volume resistivity greater than 1.0 x 105
ohm-cm but less than or equal to 1.0 x 1012 ohm-cm when
tested according to the methods of EIA 541.
Electrostatic
shielding attenuates electrostatic fields on the surface of a package in
order to prevent potential differences from being developed inside the
package. Electrostatic shielding is provided by materials that have a
surface resistance equal to or less than 1.0 x 103 when
tested according to EOS/ESD-S11.11 or a volume resistivity of equal to
or less than 1.0 x 103 ohm-cm when tested according to the
methods of EIA 541. ANSI/ESD 11.31 is used to evaluate the shielding
characteristics of bags.
Fig. 9.
Examples of ESD-protective bags
The
final element of a good static control program is the use of appropriate
symbols to identify ESD-sensitive devices and assemblies, as well as
products intended to control ESD. The two most widely accepted symbols
for identifying ESDS parts or ESD control materials are defined in ESD
Association Standard ANSI ESD S8.1-1993 - ESD Awareness Symbols.